Subject: Three Flow Divider Link Example in SWMM 5
You can have more than 2 downstream OUTLET Type links in the SWMM 5 dynamic wave solution. Each link, Under5, Over5 and ReturnFlow is an OUTLET Link with a rating curve depth/flow table. Depending on the depth in the storage node DIVIDER, the flow is computed from the table for links Under5, Over5 and Return Flow.
|
Autodesk Technologist with Information about Stormwater Management Model (SWMM) for watershed water quality, hydrology and hydraulics modelers (Note this blog is not associated with the EPA). You will find Blog Posts on the Subjects of SWMM5, ICM SWMM, ICM InfoWorks, InfoSWMM and InfoSewer.