Subject: How to Approximate a Timer in the RTC Rules of SWMM 5
SWMM 5 does not have a explicit timer in its Real Time Control (RTC) rules but you can approximate it by using a Control Curve as in the attached example model. The Control Curve will modify the setting of the Weir by the Inflow to the Storage node. You can have normal weir flow settings based on the invert elevation of the weir and the Surface node water surface elevation but in addition you can control the weir setting by:
1. Closing the weir when the inflow is low,
2. Closing the weir by staggered Storage node depth,
3. Opening the weir gradually when the inflow increases
4. Closing the weir by a combination of Node Depth IF statements and Control Curve rules
For example, you can have the Weir Setting controlled the Node Depth, Link Inflow and Node Inflow simultaneously approximately with the depth and the inflow parameters closing the weir by proxy instead of by time since the closing.
|
Autodesk Technologist with Information about Stormwater Management Model (SWMM) for watershed water quality, hydrology and hydraulics modelers (Note this blog is not associated with the EPA). You will find Blog Posts on the Subjects of SWMM5, ICM SWMM, ICM InfoWorks, InfoSWMM and InfoSewer.
Saturday, February 4, 2012
How to Approximate a Timer in the RTC Rules of SWMM 5
Subscribe to:
Post Comments (Atom)
LinkedIn algorithm prioritizes content based on several factors for SWMM5 Enablement
The LinkedIn algorithm prioritizes content based on several factors: 1. Initial Engagement (First Hour) Your post is shown to a small ...
-
@Innovyze User forum where you can ask questions about our Water and Wastewater Products http://t.co/dwgCOo3fSP pic.twitter.com/R0QKG2dv...
-
Soffit Level ( pipe technology ) The top point of the inside open section of a pipe or box conduit. The soffit is the ...
-
Engine Error Number Description ERROR 101: memory allocation error. ...
No comments:
Post a Comment