InfoSewer Inflow Control for a PUMP

InfoSewer Inflow Control for a PUMP

InfoSewer Inflow Control for a PUMP

by dickinsonre
InfoSewer Inflow Control for a PUMP

You can control the pumps in InfoSewer and H2OMap Sewer by using a Pump Control which will control the pump based on:

1.       Volume
2.      Level
3.      Discharge
4.      Inflow
5.      Time 
If you use a By Inflow control the pump speed of the pump is increased or decreased to make the Upstream Wet Well Level Constant (Figure 1).
Figure 1.  Inflow Control for  PUMP in InfoSewer and H2OMAP Sewer will change the Pump Speed of the pump to make the Wet Well level constant