Sunday, December 16, 2012

InfoSewer Inflow Control for a Pump with a Pump Curve

InfoSewer Inflow Control for a Pump with a Pump Curve

You can control the pumps in InfoSewer and H2OMap Sewer by using a Pump Control which will control the pump based on:

1.       Volume
2.      Level
3.      Discharge
4.     Inflow
5.      Time

If you use a By Inflow control the pump speed of the pump is increased or decreased to make the Upstream Wet Well Level Constant (Figure 1) for an exponential 3 point curve