Showing posts with label Maximum Surcharge Height Over Crown Explanation. Show all posts
Showing posts with label Maximum Surcharge Height Over Crown Explanation. Show all posts

Wednesday, February 8, 2012

Maximum Surcharge Height Over Crown Explanation

Note:   Maximum Surcharge Height Over Crown Explanation

Here is an example of how the Maximum Surcharge Height over the Node Crown is calculated.     Consider a manhole with an invert of 10 feet,  one incoming pipe (Pipe A), one outgoing pipe (Pipe B), both pipes with a diameter of 2 feet, but the invert  of Pipe A is 10 feet and the invert of Pipe B is 11 feet.  What is the Maximum Surcharge height if the HGL at the node is 17 feet?

                                                                                HGL at Node ---- 17 feet
                                                                                Maximum Surcharge Height Over Crown is 4 feet

                                                                                        
                                                                                Node Crown --- 13 feet         Pipe B Crown --- 13 feet                          

           Pipe A Crown --- 12 feet                          

                                                                                                                                          Pipe B Invert --- 11 feet                          
            Pipe A Invert --- 1o feet                           MH Invert --- 10 feet
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

Reasons for ICM SWMM inside of ICM alongside of ICM InfoWorks Networks

ICM SWMM vs. SWMM5 ICM SWMM directly uses the EPA SWMM5 engine, making it functionally equivalent to SWMM5 in terms of calculations and perf...