Here is an example of how the Maximum Surcharge Height over the Node Crown is calculated.     Consider a manhole with an invert of 10 feet,  one incoming pipe (Pipe A), one outgoing pipe (Pipe B), both pipes with a diameter of 2 feet, but the invert  of Pipe A is 10 feet and the invert of Pipe B is 11 feet.  What is the Maximum Surcharge height if the HGL at the node is 17 feet?

                                                                                HGL at Node ---- 17 feet
                                                                                Maximum Surcharge Height Over Crown is 4 feet

                                                                                        
                                                                                Node Crown --- 13 feet         Pipe B Crown --- 13 feet                          

           Pipe A Crown --- 12 feet                          

                                                                                                                                          Pipe B Invert --- 11 feet                          
            Pipe A Invert --- 1o feet                           MH Invert --- 10 feet
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++