Showing posts with label Two new parameters and a modified table in InfoSWMM 11 and H2OMAP SWMM. Show all posts
Showing posts with label Two new parameters and a modified table in InfoSWMM 11 and H2OMAP SWMM. Show all posts

Friday, April 15, 2011

Two new parameters and a modified table in InfoSWMM 11 and H2OMAP SWMM

Subject:  Two new parameters and a modified table in InfoSWMM 11 and H2OMAP SWMM v10  that does the following:

1.   Allows you to control the maximum number of iterations in the solution,
2.   Controls the Stopping tolerance (internal units of feet) for node iterations, and
3.   Shows not only the percent continuity error at a node but the error in million gallons (Mgal)

If you have a high continuity error or want to reduce your existing continuity error then you can increase the number of iterations or lower the stopping tolerance so that at each time step there is less continuity error. 


Reasons for ICM SWMM inside of ICM alongside of ICM InfoWorks Networks

ICM SWMM vs. SWMM5 ICM SWMM directly uses the EPA SWMM5 engine, making it functionally equivalent to SWMM5 in terms of calculations and perf...